Model
Model |
Suffix code |
Optional Suffix code |
Description |
|||||
| UT35A | Digital Indicating Controller (provided with retransmission output or 15 V DC loop power supply, 2 DIs, and 3 DOs) (Power supply: 100-240 V AC) | |||||||
| Basic control | -0 | Standard type | ||||||
| -1 | Position proportional type | |||||||
| -2 | Heating/cooling type | |||||||
| Functions | 0 | None | ||||||
| 1 | 2 additional DIs and 2 additional DOs | |||||||
| 2 | 5 additional DIs and 5 additional DOs | |||||||
| Open networks | 0 | None | ||||||
| 1 | RS-485 communication (Max. 38.4 kbps, 2-wire/4-wire) | |||||||
| 2 | Ethernet communication (with serial gateway function) | |||||||
| 3 | CC-Link communication (with Modbus master function) | |||||||
| 4 | PROFIBUS-DP communication (with Modbus master function) |
|||||||
| 5 | DeviceNet communication (with Modbus master function) *Coming soon! |
|||||||
| Display language (*1) | -1 | English | ||||||
| -2 | German | |||||||
| -3 | French | |||||||
| -4 | Spanish | |||||||
| Case color | 0 | White (Light gray) | ||||||
| 1 | Black (Light charcoal gray) | |||||||
| -00 | Always "-00" | |||||||
| Options | /LP | 24 VDC loop power supply (*2) | ||||||
| /HA | Heater break alarm (*3) | |||||||
| /DC | Power supply 24 VAC/DC | |||||||
| /CT | Coating (*4) | |||||||
* 1: English, German, French, and Spanish can be displayed as the guide display.
* 2: The /LP option can be specified in combination with function code "0" or "1" and open network code "0" or "1."
* 3: The /HA option can be specified when basic control code is "-0" or "-2."
* 4: When the /CT option is specified, the UT35A does not conform to the safety standards (UL and CSA) and CE marking.
UT32A (1/8 DIN Size)
Model |
Suffix code |
Optional
Suffix code |
Description |
|||||
| UT32A | Digital Indicating Controller (provided with retransmission output or 15 V DC loop power supply, 2 DIs, and 3 DOs) (Power supply: 100-240 V AC) | |||||||
| Basic control | -0 | Standard type | ||||||
| -1 | Position proportional type | |||||||
| -2 | Heating/cooling type | |||||||
| Functions | 0 | None | ||||||
| 1 | RS-485 communication (Max. 38.4 kbps, 2-wire/4-wire) (*2) | |||||||
| 2 | 2 additional DIs and 2 additional DOs | |||||||
| Open networks | 0 | None | ||||||
| Display language (*1) | -1 | English | ||||||
| -2 | German | |||||||
| -3 | French | |||||||
| -4 | Spanish | |||||||
| Case color | 0 | White (Light gray) | ||||||
| 1 | Black (Light charcoal gray) | |||||||
| -00 | Always "-00" | |||||||
| Options | /LP | 24 VDC loop power supply (*2) | ||||||
| /HA | Heater break alarm (*3) | |||||||
| /DC | Power supply 24 VAC/DC | |||||||
| /CT | Coating (*4) | |||||||
* 1: English, German, French, and Spanish can be displayed as the guide display.
* 2: The /LP option can be specified in combination with basic control code "-0" or "-1" and
function code "0" or "1." Futhermore, when the function code is "1," the RS-485 communication is 2-wire system.
* 3: The /HA option can be specified when basic control code is "-0" or "-2."
* 4: When the /CT option is specified, the UT32A does not conform to the safety standards (UL and CSA) and CE marking.